Features:
The meter can be used for testing power, voltage, current, peak value, phase, frequency, power factor, phase angle, and reaction factor, etc. of single-/three-phase circuit; automatic phase sequence testing is possible for 3-phase measurement.
True effective value measurement: accurate measurement is possible even with serious distortion in current waveform.
Low-consumption high-speed single-chip microprocessor is employed and sophisticated algorithm is applied, as a result, results can be obtained rapidly and precisely, and up to 20 harmonics and distortion value thereof can be measured.
General specification:- Max. common-mode voltage: 600V AC RMS
- Mode of display: LCD display; Max. reading: 6000
- Range selection: Fully automatic range selection
- Frequency detection: automatic (when harmonic is serious, it is better to use manual settings for testing frequency so as to assure the reading stability)
- Over-range display: “OL”
- Data holding: “HOLD” is shown on LCD
- Power supply: 3 batteries of 1.5 V, AAA
- Power consumption: 250 mW
- Storage temperature: - 20 °C ~ 70 °C
- Operating temperature: 0 °C ~ 40 °C
- Temperature Coefficient:0.05×(specified accuracy)per°C
- Electromagnetic Compatibility: In an RF field of 3V/M,accuracy=specified accuracy , Otherwise accuracy is unspecifieced.
- Operating Altitude: 2000m CAT Ⅲ 600V;3000m CAT Ⅱ600V
- Store Altitude: 12000m
- Dimensions: 208mm×78mm×35mm
- Weight: about 350 g (with battery)
Technical specification:
Accuracy: ±(% read + graduation #) ambient temperature: 18°C ~ 28°C, Humidity 80%, frequency for voltage, current: 45 Hz ~ 65 Hz
AC Voltage RMS
RangeAccuracy
Resolution
Input impedance
10V-600V
±(1.0%+5)
0.1V
1 MΩ //
10 pFMax. allowed overload voltage: 750 V (RMS)
AC Current RMS
RangeAccuracy
Resolution
2mA-3999mA
±(2%+5)
0.01mA
4A-200A
±(2%+5)
0.01A
Max. allowed overload current: 200 A
Single-phase active power (W)
RangeAccuracy
Resolution
0.01W-120KW
±(3%+5)
0.01W
Min. test current: 10mA; Min. test voltage: 10V
Power factor
RangeAccuracy
Resolution
0.3~1 Capacitive
±(0.02+2)
0.001
0.3~1 Inductive
±(0.02+2)
0.001
Min. test current: 10mA; Min. test voltage: 10V
Passive power (VAr) 2=(VA) 2+W 2
RangeAccuracy
Resolution
0.01W-120KW
±(3%+5)
0.01VAr
Min. test current: 10mA; Min. test voltage: 10V
Passive power Var is calculated according to the measured V, A, and kW value。
Frequency (Hz)
RangeAccuracy
Resolution
30Hz~1kHz
0.5%+1
0.1Hz
Min. test current: 10mA; Min. test voltage: 10V
Harmonic test
Harmonic numberPrecision of harmonic voltage
1
±(3.0%+10)
2-6
±(3.5%+10)
7-8
±(4.5%+10)
9-10
±(5.0%+10)
11-15
±(7%+10)
16-20
±(10%+10)
Min. test current: 20mA; Min. test voltage: 20V
Item show:
Accessories:
User Manual ×1
Battery 1.5V AA A Battery ×3
Test Leads ×1
Test clip ×2(Red,Black)