MASTECH®

MS5308 Portable Handheld AutoRange LCR Meter

Write a Review
 
US $184.69
Qty:
United states Via Estimate shipping fee
· Orders over USD$ 50.00 will get free tracking services via air mail
This MS5308 LCR digital bridge meter is a professional instrument for measuring inductance, capacitance and resistance. It has many features, such as automatic identification, automatic measurement range, high measurement accuracy and speed, wide measuring range and so on. An ordinary multimeter only provides DC mode for resistance measurement, while the MS5308 provides both AC and DC measurement modes. A variety of test frequencies up to 100Khz can be provided for inductance, capacitance and resistance in AC mode to meet the actual needs better. Correct usage can ensure that the instrument will work precisely for a long time. Please read the instructions carefully before using and operate the instrument strictly in accordance with the instructions .

Customers Also Bought

  • HM TDS / PH Monitor

Product Description

Customers' Reviews
More Information

  • Description:

    Definition Description:

    APO: Auto power off
    LCR: This character showing on the LCD means that the tester works in automatic identification mode
    LP: Inductance parallel connection measurement mode
    Ls: Inductance series connection measurement mode
    CP: Capacitance parallel connection measurement mode
    Cs: Capacitance series connection measurement mode
    RP: Resistance parallel connection measurement mode
    Rs: Resistance series connection measurement mode
    DCR: Resistance DC measurement mode
    D: Wastage factor
    Q: Quality factor
    θ: Phase angle value
    ESR: Equivalent resistance
    DUT: Object for measuring

    Impedance parameter description
    (see Figure Ⅰ)

    Z= Rs+jXs=|Z|∠θ  Rs-=|Z|Cosθ  Xs= |Z|Sinθ
    Xs /Rs=Tanθ  θ=Tan-1 (Xs /Rs)
    If θ > 0, it means that the measured object is resistant, if θ < 0, it means that that the measured object is capacitive.



    Series-parallel connection mode description


    This meter has series and parallel measurement modes. When the capacitance value of the measured object is large or inductance value is small, use the series mode for more accurate results. When the capacitance value of the measured object is small or inductance value is large, use the parallel mode for more accurate results. This meter can select the measurement mode automatically according to the measured object.

    Functional characteristics description:

    1. 19,999 (main)/1,999 (secondary) dual LCD display
    2. LCR measures with automatic identification and automatic measurement range
    3. L\C\R single measurement selection
    4. Resistance measurement in DCR mode
    5. D/Q/θ/ESR display on the secondary display
    6. Series or parallel measurement modes are selectable
    7. Comparison function under single measurement
    8. Test frequency 100/120/1k/10k/100k is selectable in AC mode
    9. The selection feature for measured components with the same series
    10. Battery power display, auto power off if meter is not operated for 5 minutes.
    11. With infrared transmission interface, the meter is secure (supporting hot plug). With special software, the meter is easily managed.
    12. See table 1-3 for measurement accuracy and scope

    Remarks: This accuracy is the measurement standard. In DUT jack, the meter-specific probe should be used if required. Measurement with probe may be influenced by external environment. To avoid inaccurate measurements, please keep away from strong magnetic sources.

    Table 1 Resistance measurement scope


    Measurement item

    Measurement frequency

    Measurement scope

    Resolution

    Accuracy

     

     

     

     

     

     

    RS/RP

    100Hz/120 Hz

    200.00Ω

    0.01Ω

    1.0%+5d

    100Hz/120 Hz

    2.0000KΩ

    0.1Ω

    0.3%+5d

    100Hz/120 Hz

    20.000KΩ

    0.3%+5d

    100Hz/120 Hz

    200.00KΩ

    0.01kΩ

    0.5%+5d

    100Hz/120 Hz

    2.0000MΩ

    0.1kΩ

    1.0%+5d

    100Hz/120 Hz

    20.000MΩ

    1kΩ

    1.0%+5d

    100Hz/120 Hz

    200.00MΩ

    0.1MΩ

    2.0%+5d

    1kHz

    20.000Ω

    0.001Ω

    1.0%+5d

    1kHz

    200.00Ω

    0.01Ω

    0.3%+5d

    1kHz

    2.0000KΩ

    0.1Ω

    0.3%+5d

    1kHz

    20.000KΩ

    0.3%+5d

    1kHz

    200.00KΩ

    0.01kΩ

    0.5%+5d

    1kHz

    2.0000MΩ

    0.1kΩ

    1.0%+5d

    1kHz

    20.000MΩ

    1kΩ

    2.0%+5d

    1kHz

    200.0MΩ

    0.1MΩ

    5.0%+5d

    10kHz

    20.000Ω

    0.001Ω

    1.0%+5d

    10kHz

    200.00Ω

    0.01Ω

    0.5%+5d

    10kHz

    2.0000KΩ

    0.1Ω

    0.3%+5d

    10kHz

    20.000KΩ

    0.5%+5d

    10kHz

    200.00KΩ

    0.01kΩ

    1.0%+5d

     

    100kHz

    20.000Ω

    0.001Ω

    1.0%+5d

    100kHz

    200.00Ω

    0.01Ω

    1.0%+5d

    100kHz

    2.0000KΩ

    0.1Ω

    1.0%+5d

    100kHz

    20.000KΩ

    2.0%+5d

     


























































     

    Note: This accuracy is the measurement standard when D <0.1, if D> 0.1, it should be multiplied by the extraction of a root of 1 + D2

    Table 2 Capacitance measurement scope


    Measurement item

    Measurement frequency

    Measurement scope

    Resolution

    Accuracy

     

     

     

     

     

     

    CS/CP

    100Hz/120 Hz

    20.000nF

    1pF

    1.0%+5d

    100Hz/120 Hz

    200.00nF

    0.01nF

    0.5%+5d

    100Hz/120 Hz

    2000.0nF

    0.1nF

    0.5%+5d

    100Hz/120 Hz

    20.000uF

    1nF

    0.5%+5d

    100Hz/120 Hz

    200.00uF

    0.01uF

    1.0%+5d

    100Hz/120 Hz

    2000.0uF

    0.1uF

    2.0%+5d

    100Hz/120 Hz

    20.00mF

    0.1mF

    2.0%+5d

    1kHz

    2000.0pF

    0.1pF

    1.0%+5d

    1kHz

    20.000nF

    1pF

    1.0%+5d

    1kHz

    200.00nF

    0.01nF

    0.5%+5d

    1kHz

    2000.0nF

    0.1nF

    0.5%+5d

    1kHz

    20.000uF

    1nF

    0.5%+5d

    1kHz

    200.00uF

    0.01uF

    1.0%+5d

    1kHz

    2000.0uF

    0.1uF

    1.0%+5d

    10kHz

    200.00 pF

    0.01pF

    1.0%+5d

    10kHz

    2000.0pF

    0.1pF

    1.0%+5d

    10kHz

    20.000nF

    1pF

    1.0%+5d

    10kHz

    200.00nF

    0.01nF

    1.5%+5d

    10kHz

    2000.0nF

    0.1nF

    2.0%+5d

    100kHz

    200.00 pF

    0.01pF

    2.0%+5d

    100kHz

    2000.0pF

    0.1pF

    1.0%+5d

    100kHz

    20.000nF

    1pF

    2.0%+5d

    100kHz

    200.00nF

    0.01nF

    5.0%+5d





















































    Note:
    This accuracy is the measurement standard. When D <0.1, if D> 0.1, it should be multiplied by the extraction of a root of 1 + D2

    Table 3. Inductance measurement scope


    Measurement item

    Measurement frequency

    Measurement scope

    Resolution

    Accuracy

     

     

     

     

     

     

    LS/LP

    100Hz/120 Hz

    20.000mH

    1uH

    1.0%+5d

    100Hz/120 Hz

    200.00mH

    0.01mH

    0.5%+5d

    100Hz/120 Hz

    2000.0mH

    0.1mH

    0.5%+5d

    100Hz/120 Hz

    20.000H

    1mH

    0.5%+5d

    100Hz/120 Hz

    200.00H

    0.01H

    1.0%+5d

    100Hz/120 Hz

    2000.0H

    0.1H

    1.0%+5d

    100Hz/120 Hz

    20.000kH

    1H

    2.0%+5d

    1kHz

    2000.0uH

    0.1uH

    1.0%+5d

    1kHz

    20.000mH

    1uH

    0.5%+5d

    1kHz

    200.00mH

    0.01mH

    0.5%+5d

    1kHz

    2000.0mH

    0.1mH

    1.0%+5d

    1kHz

    20.000H

    1mH

    1.0%+5d

    1kHz

    200.00H

    0.01H

    2.0%+5d

    1kHz

    2000.0H

    0.1H

    5.0%+5d

    10kHz

    200.00 uH

    0.01uH

    1.0%+5d

    10kHz

    2000.0uH

    0.1uH

    0.5%+5d

    10kHz

    20.000mH

    1uH

    0.5%+5d

    10kHz

    200.00mH

    0.01mH

    1.5%+5d

    10kHz

    2000.0mH

    0.1mH

    2.0%+5d

    10kHz

    20.000H

    0.001H

    5.0%+5d

    100kHz

    20.000 uH

    0.001uH

    1.0%+5d

    100kHz

    200.00 uH

    0.01uH

    2.0%+5d

    100kHz

    2000.0uH

    0.1uH

    2.0%+5d

    100kHz

    20.000mH

    1uH

    2.0%+5d

    100kHz

    200.00mH

    0.01mH

    5.0%+5d


























































    Note: This accuracy is the measurement standard. When D <0.1, if D> 0.1, it should be multiplied by the extraction of a root of 1 + D2

    Item Show:

    MASTECH MS5308 Portable Handheld AutoRange LCR Meter

    Accessories

    MS5308 LCR digital bridge meter  
    Kelvin
    test clip (one pair)
    SMD test probe                 
    IR data line
    Upper computer program CD      
    External power supply


Payment Method
Return Policy

• If the order has not been shipped; please contact DinoDirect Live Support for order cancellation.You will get your refund within 24 hours.
• If the order has already been shipped; you may return the item to us postmarked within 30 calendar days of delivery. Please contact our Live Support to inform that.
• Please contact Live Chat or click here to learn more return policy.

Copyright DinoDirect Corporation 2014. All rights reserved. See our privacy policy, terms of use, disclaimer and takedown policy.
Sign In submit Submit Apply >> Continue Join Now Add Store To Wishlist Add a new address Back >> Continue checkout Save Cancel Remove/Change Items Add To Cart Shop Now Create Register now Open a Case Start a Live Chat View all < Create An Account Return to Sign in Send Confirmed Application Email Verification Get It GO Enter My iDinor Life! Close Join My Homepage Continue Shopping Share Rewards Accept Accept and Check >> Search Back Close the case Pay Now Cancel Submit Confirm Save Click for more info Write a Review Yes No Reply Sold Out Size Guide Color Guide No thanks Continue Upload Share Rewards Accept and Check >> Search view more Next et Transaction Code >> Confirm Remove Upload Video Upload Images >> Continue checkout Get Free Sample Write a feedback Buy Now OK Start Chat Create An Account No, thanks! Go Remind me 7 days later